Availability: | |
---|---|
Quantity: | |
GD-R2222
GOLD
GD-R2222
GD-R2222 Biodiesel Rancimat Oxidation Stability Tester
Introduction:
The rancimat oxidation stability tester can quickly, accurately and intuitively determine the oxidative stability of oils and fats, widely applied to the elevant departments and enterprises research on the processing, use, storage of oils and fats, the selection of oils for food production, the use of antioxidants and synergists, and the oxidation stability research of environmentally friendly vehicle fuel oil fatty acid methyl ester FAME, etc.
Features:
1. Designed and made according to EN 14112 standard, suitable for measuring the oxidation stability of oils and fats.
2. Conform to EU standard, Chinese standards and related standards.
3. The rancimat oxidation stability tester adopts the imported digital display PID temperature controller, the temperature control range is stable at normal temperature ~ 150℃, the accuracy is stable at ± 0.1 ℃.
4. It adopts the imported special heating belt, more reflects safety and environmental protection.
5. It adopts special diaphragm pump, accurate flow control and measurement, constant flow.
6. Unique air filtration system to ensure the smoothness of multiple air channels and excellent air source.
7. Conductivity meter real-time measurement data, large screen LCD industrial computer automatically records and stores data, multi-channel data input and processing, real-time display of oil oxidation process and conductivity during induction period.
Display mode: curve/digital two modes.
8. Each measurement is stored in the database. The data related to the curve and the data related to the entire method can be called at any time. Even after a long period of time, you can still apply the measurement points in the previous measurement to the current experiment .
9. Result processing: automatic measurement, manual thread trimming.
10. Working unit: two tubes
11. Each sample is controlled individually and can be set automatically according to requirements.
Application:
1. Biodiesel production enterprises
2. Related testing department
Reference Standards:
1. NB/SH/T0873 Standard test method of determination of oxidation stability of biodiesel and blends with diesel fuel by accelerated oxidation method.
2. NB/SH/T0825 Standard test method for determination of oxidation stability of Fatty Acid Methyl Ester by accelerated oxidation test.
3. EN 14112 Fat and oil derivatives - Fatty Acid Methyl Esters (FAME) - Determination of oxidation stability (accelerated oxidation test).
4. GB/T21121 Animal and vegetable fats and oils - Determination of oxidation stability (accelerated oxidation test).
Technical Parameters:
Model No. | GD-R2222 Rancimat Oxidation Stability Tester |
Applicable standards | EN 14112, NB/SH/T0873, NB/SH/T0825, GB/T21121 |
Temperature control | PID digital display temperature controller, temperature control separately. |
Gas source | Special diaphragm pump, 10L/H |
Temperature control mode | Electric heating rod |
Working temperature | Normal temperature ~ 150±0.1℃ |
Results processing | Automatic measurement, storage, manual thread trimming |
Working unit | Two tubes, separate testing for easy testing of parallel samples |
Power supply | AC220V±10%, 50HZ |
Total power | 2.5KW |
Net weight | 23KG |
GD-R2222 Biodiesel Rancimat Oxidation Stability Tester
Introduction:
The rancimat oxidation stability tester can quickly, accurately and intuitively determine the oxidative stability of oils and fats, widely applied to the elevant departments and enterprises research on the processing, use, storage of oils and fats, the selection of oils for food production, the use of antioxidants and synergists, and the oxidation stability research of environmentally friendly vehicle fuel oil fatty acid methyl ester FAME, etc.
Features:
1. Designed and made according to EN 14112 standard, suitable for measuring the oxidation stability of oils and fats.
2. Conform to EU standard, Chinese standards and related standards.
3. The rancimat oxidation stability tester adopts the imported digital display PID temperature controller, the temperature control range is stable at normal temperature ~ 150℃, the accuracy is stable at ± 0.1 ℃.
4. It adopts the imported special heating belt, more reflects safety and environmental protection.
5. It adopts special diaphragm pump, accurate flow control and measurement, constant flow.
6. Unique air filtration system to ensure the smoothness of multiple air channels and excellent air source.
7. Conductivity meter real-time measurement data, large screen LCD industrial computer automatically records and stores data, multi-channel data input and processing, real-time display of oil oxidation process and conductivity during induction period.
Display mode: curve/digital two modes.
8. Each measurement is stored in the database. The data related to the curve and the data related to the entire method can be called at any time. Even after a long period of time, you can still apply the measurement points in the previous measurement to the current experiment .
9. Result processing: automatic measurement, manual thread trimming.
10. Working unit: two tubes
11. Each sample is controlled individually and can be set automatically according to requirements.
Application:
1. Biodiesel production enterprises
2. Related testing department
Reference Standards:
1. NB/SH/T0873 Standard test method of determination of oxidation stability of biodiesel and blends with diesel fuel by accelerated oxidation method.
2. NB/SH/T0825 Standard test method for determination of oxidation stability of Fatty Acid Methyl Ester by accelerated oxidation test.
3. EN 14112 Fat and oil derivatives - Fatty Acid Methyl Esters (FAME) - Determination of oxidation stability (accelerated oxidation test).
4. GB/T21121 Animal and vegetable fats and oils - Determination of oxidation stability (accelerated oxidation test).
Technical Parameters:
Model No. | GD-R2222 Rancimat Oxidation Stability Tester |
Applicable standards | EN 14112, NB/SH/T0873, NB/SH/T0825, GB/T21121 |
Temperature control | PID digital display temperature controller, temperature control separately. |
Gas source | Special diaphragm pump, 10L/H |
Temperature control mode | Electric heating rod |
Working temperature | Normal temperature ~ 150±0.1℃ |
Results processing | Automatic measurement, storage, manual thread trimming |
Working unit | Two tubes, separate testing for easy testing of parallel samples |
Power supply | AC220V±10%, 50HZ |
Total power | 2.5KW |
Net weight | 23KG |