The Atomic Absorption Spectrophotometer can be used for flame atomic absorption spectrometry analysis and is widely used in geology, metallurgy, non-ferrous metals, environmental protection, quality supervision, food, medicine, disease control, chemical industry and other industries to carry out element trace and trace analysis.
Availability:
Quantity:
  • GD-4530F

  • GOLD

  • AAS

Atomic Absorption Spectrophotometer


Introduction:

The Atomic Absorption Spectrophotometer can be used for flame atomic absorption spectrometry analysis and is widely used in geology, metallurgy, non-ferrous metals, environmental protection, quality supervision, food, medicine, disease control, chemical industry and other industries to carry out element trace and trace analysis. 


Features:

1. Win7, Win10 and other environment English software, easy to use, friendly interface, support data output and editing in Excel, Word and other formats, built-in expert database system, avoid reading manuals during the analysis process.

2. The AAS adopts a fully automatic lamp stand with 8 lamp positions (optional 2 lamp positions can be plugged into a high-performance hollow cathode lamp), with functions such as automatic rotation, automatic switching and collimation, and multi-lamp lighting and preheating.

3. The AAS has various automatic and intelligent functions such as automatic peak-finding setting and scanning, automatic setting of slit width and energy, automatic wavelength optimization, and no need to reset when switching wavelengths.

4. The instrument has a built-in reliable safety monitoring and protection system, which monitors the flame state in real time, and has the functions of automatic flameout and alarm protection when abnormal air pressure, gas leakage, etc. are abnormal.

5. The AAS supports the expansion of various functions and accessories such as hydride method, flame emission method, oxygen-enriched air-acetylene high temperature flame method, and flame autosampler.

6. Note: The slit group and wavelength scanning mechanism of the instrument are key components, and users should not adjust, repair, modify or replace them by themselves.


Main Parameters:

1. Wavelength range: working wavelength 190nm~900nm.

2. Light source system: 8 lamp position design (can be extended to 2 lamp positions to connect high-performance hollow cathode lamps).

The Atomic Absorption Spectrophotometer has functions such as automatic rotation of the lamp stand, automatic switching and automatic collimation, and supports multi-lamp lighting.

3. Optical system: Czerny-Turner type monochromator, grating line density 1800/mm, blaze wavelength 250nm.

Focal length: 277mm.

Spectral bandwidth: 0.1nm/0.2nm/0.4nm/0.8nm/1.6nm/2.4nm six gears automatic switching;

Automatic peak setting and scanning, automatic setting of slit and energy, automatic wavelength optimization.

4. Atomizer: The single flame atomization system is adopted, and the burner can be adjusted up and down, back and forth, and rotated in multiple dimensions.

10cm all-titanium burner for air-acetylene flame (optional flame-emitting combustion head);

Adopt high-reliability gas flow control system, with automatic control such as automatic ignition/extinguishing.

With foot reading function, effectively liberate the hands of analysts.

5. Protection measures: real-time monitoring of flame state, air pressure, etc., automatic flameout and gas circuit and alarm when abnormal.

After the instrument is powered on, it monitors gas leakage in real time, and automatically shuts off the gas circuit and alarms when it is abnormal.

6. Software communication: all English intelligent operation software, support Win7/Win10 and other operating systems.

The instrument status is automatically optimized with one key, and it supports multi-task analysis.

Automatically fit the working curve, automatically reset the slope, automatically calculate the concentration, sample content, etc.

The measurement is repeated 1 to 99 times, and the average, standard deviation and relative standard deviation are automatically calculated.

Test data or final analysis report, etc., support direct printing or export and editing in Excel and Word.

7. Dimensions and weight: The size of the instrument host is about 1010mm(L)×480mm(W)×550mm(H), and the weight is about 65kg.

8. Equipment power: The instrument host adopts single-phase alternating current (220V±22V), and the average power consumption is less than or equal to 0.3kVA.


Previous: 
Next: 
Product Inquiry

Gold Mechanical & Electrical Equipment

We're here to offer you professional, fast, comprehensive and high-quality services.
Our marketing network covers all countries worldwide and thus can provide high-quality pre-sale, in-sale and after-sale services for customers as soon as possible. 

Products

Quick Links

​Copyright © Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd.  All Rights Reserved. Site Map  Supported by Leadong.com