GD-BK600 Fully-Automatic Open Cup and Closed Cup Flash Point Tester
GD-BK600 automatic open and closed flash point meter is designed and made as per ASTMD93 and ASTM D92 standard. Usually used in petroleum, chemical, electric power, environmental protection, railway, scientific research and other departments. it is the ideal instrument for testing open and closed port flash point.
Main feature:
1. Adopt new high-speed signal processor control, self-adaptive PID control algorithm, automatically adjust the heating curve according to standard requirements;
2. lifting, stirring, ignition, detection, alarm, cooling and printing instruments is completed fully-automatic;
3. Safe and no gas source. platinum alloy heating wire ignition method, safe, stable, reliable, and high test accuracy; 4. Differential detection, automatic correction of system deviation, automatic stop detection and alarm when the temperature exceeds the value;
5. Powerful storage function, convenient for historical check.
Main Parameter:
Display method | 8-inch English touch screen display |
Measurement Method | Thermocouple differential detection type |
Display range | 59.9~400℃ |
Measuring range | Open cup: ambient~400 ℃ ; Closed cup:ambient~350℃ |
Resolution | 0.1℃ |
Repeatability | Flash point ≤110℃, the tolerance is ±1°C; flash point>110℃, the tolerance is ±2°C |
Printer | Low power consumption high speed thermal printer, 56mm paper width |
Temperature check | Imported platinum resistance (Pt100Ω) |
Ignition method | No gas, Electronic Ignition |
Self-check function | Instrument fault automatic diagnosis |
Cooling method | air cooling |
Power Consumption | <550W |
Environment | 10~45℃,humidity 30~80% |
Power supply | AC220V±10% |
GD-BK600 Fully-Automatic Open Cup and Closed Cup Flash Point Tester
GD-BK600 automatic open and closed flash point meter is designed and made as per ASTMD93 and ASTM D92 standard. Usually used in petroleum, chemical, electric power, environmental protection, railway, scientific research and other departments. it is the ideal instrument for testing open and closed port flash point.
Main feature:
1. Adopt new high-speed signal processor control, self-adaptive PID control algorithm, automatically adjust the heating curve according to standard requirements;
2. lifting, stirring, ignition, detection, alarm, cooling and printing instruments is completed fully-automatic;
3. Safe and no gas source. platinum alloy heating wire ignition method, safe, stable, reliable, and high test accuracy; 4. Differential detection, automatic correction of system deviation, automatic stop detection and alarm when the temperature exceeds the value;
5. Powerful storage function, convenient for historical check.
Main Parameter:
Display method | 8-inch English touch screen display |
Measurement Method | Thermocouple differential detection type |
Display range | 59.9~400℃ |
Measuring range | Open cup: ambient~400 ℃ ; Closed cup:ambient~350℃ |
Resolution | 0.1℃ |
Repeatability | Flash point ≤110℃, the tolerance is ±1°C; flash point>110℃, the tolerance is ±2°C |
Printer | Low power consumption high speed thermal printer, 56mm paper width |
Temperature check | Imported platinum resistance (Pt100Ω) |
Ignition method | No gas, Electronic Ignition |
Self-check function | Instrument fault automatic diagnosis |
Cooling method | air cooling |
Power Consumption | <550W |
Environment | 10~45℃,humidity 30~80% |