Availability: | |
---|---|
Quantity: | |
GD--KS102
GOLD
Open Cup Flash Point Tester
The GD-KS102 automatic open flash point tester is designed and manufactured according to the requirements of GB/T3536 and ASTM D92 standards. This instrument has a high degree of automation, capable of automatic lifting, automatic temperature control, automatic ignition, automatic measurement, automatic printing, intelligent flame holding, and automatic forced cooling.
Work environment:
Working power supply | AC220V ± 10% 50Hz ± 10% |
Environmental temperature | 10-40 ℃ |
Relative humidity | <80% R |
Other | There is no strong vibration, airflow, strong electromagnetic interference, or corrosive gas around the laboratory. |
Standard:
ASTM D92 is a standard method developed by the American Society for Testing and Materials (ASTM) for determining the flash point and ignition point of liquids using the Cleveland Open Cup method. It is mainly used to evaluate the flammability characteristics of flammable liquids such as petroleum products, lubricants, and fuel oils, providing key technical basis for industrial safety, product quality control, and transportation and storage specifications.
Technical Parameter:
Measurement range | Room temperature to 400 ℃ |
Repeatability | ≤ 4 ℃ |
Reproducibility | ≤ 8 ℃ |
Resolution | 0.1 ℃ |
Heating rate | Compliant with GB/T3536 and ASTM D92 standards |
Furnace cooling | Forced air cooling |
Ignition method | Gas electric integrated ignition head, software controlled free switching |
Flame holding | Intelligent detection and automatic ignition |
Whole machine power consumption | ≤ 400W |
Host size | 450 × 375 × 360 (mm) |
Features:
1. Equipped with an 8-inch color high-definition LCD touch screen and a fully Chinese human-machine dialogue interface.
2. Parameters such as temperature, sample name, and delayed temperature can be preset.
3. Accurately simulate and track the function curve of temperature and test time in real-time, and the software has a Chinese prompt for error correction.
4. The Open Cup Flash Point Tester comes with an atmospheric pressure sensor that automatically calibrates the impact of atmospheric pressure on the test results.
5. Adopting a gas electric integrated ignition head, electric ignition and gas ignition can be freely switched by software control without the need to replace any hardware.
6. Fully automatic rotating lifting arm, lifting, scanning, detecting, and printing data are automatically completed.
7. The forced cooling system quickly cools down the heating system, and the next test can be conducted within 10 minutes.
8. The silicon nitride ignition head automatically ignites without the need for manual use of an ignition gun.
9. Open Cup Flash Point Tester has flame detection and automatic ignition function, achieving intelligent flame maintenance and greatly extending the service life of the ignition head.
10. Open Cup Flash Point Tester can be connected to the LIMS system through a USB interface.
Product details display of the Open Cup Flash Point Tester:
Open Cup Flash Point Tester
The GD-KS102 automatic open flash point tester is designed and manufactured according to the requirements of GB/T3536 and ASTM D92 standards. This instrument has a high degree of automation, capable of automatic lifting, automatic temperature control, automatic ignition, automatic measurement, automatic printing, intelligent flame holding, and automatic forced cooling.
Work environment:
Working power supply | AC220V ± 10% 50Hz ± 10% |
Environmental temperature | 10-40 ℃ |
Relative humidity | <80% R |
Other | There is no strong vibration, airflow, strong electromagnetic interference, or corrosive gas around the laboratory. |
Standard:
ASTM D92 is a standard method developed by the American Society for Testing and Materials (ASTM) for determining the flash point and ignition point of liquids using the Cleveland Open Cup method. It is mainly used to evaluate the flammability characteristics of flammable liquids such as petroleum products, lubricants, and fuel oils, providing key technical basis for industrial safety, product quality control, and transportation and storage specifications.
Technical Parameter:
Measurement range | Room temperature to 400 ℃ |
Repeatability | ≤ 4 ℃ |
Reproducibility | ≤ 8 ℃ |
Resolution | 0.1 ℃ |
Heating rate | Compliant with GB/T3536 and ASTM D92 standards |
Furnace cooling | Forced air cooling |
Ignition method | Gas electric integrated ignition head, software controlled free switching |
Flame holding | Intelligent detection and automatic ignition |
Whole machine power consumption | ≤ 400W |
Host size | 450 × 375 × 360 (mm) |
Features:
1. Equipped with an 8-inch color high-definition LCD touch screen and a fully Chinese human-machine dialogue interface.
2. Parameters such as temperature, sample name, and delayed temperature can be preset.
3. Accurately simulate and track the function curve of temperature and test time in real-time, and the software has a Chinese prompt for error correction.
4. The Open Cup Flash Point Tester comes with an atmospheric pressure sensor that automatically calibrates the impact of atmospheric pressure on the test results.
5. Adopting a gas electric integrated ignition head, electric ignition and gas ignition can be freely switched by software control without the need to replace any hardware.
6. Fully automatic rotating lifting arm, lifting, scanning, detecting, and printing data are automatically completed.
7. The forced cooling system quickly cools down the heating system, and the next test can be conducted within 10 minutes.
8. The silicon nitride ignition head automatically ignites without the need for manual use of an ignition gun.
9. Open Cup Flash Point Tester has flame detection and automatic ignition function, achieving intelligent flame maintenance and greatly extending the service life of the ignition head.
10. Open Cup Flash Point Tester can be connected to the LIMS system through a USB interface.