Micro Automatic Karl Fischer Micro Moisture Analyzer
This instrument adopts Karl Fischer Coulometric method. It owns advantages of high testing accuracy, good repeatability, low testing cost etc. It is used to accurately test trace water content in various liquid, solid and gases. And it is widely applied to petroleum, chemical engineering, pharmacy, electricity, scientific research, education department and so on.
Features:
1. Intelligent judgment: powerful next-generation processors; Dual CPU design. Separate electrolytic electrodes and measuring electrodes through dual power channels; Automatically eliminate various interferences; Greatly improved the accuracy of test results. Measure electrode data and directly perform A/D sampling conversion; The true value of the data avoids errors caused by analog circuits; The results are more accurate.
2. Easy to operate: Touch screen operation, only one press is needed to automatically complete the test and display the report value.
3. Background compensation: High current background compensation. The standby time can be shortened to less than 10 minutes.
4. Speed control: software adjusts the mixing speed; Choose between 0 and 36.
5. Endpoint indication: character prompt and buzzer
6. Comprehensive calculation function: automatic display, calculation, printing of ppm/percentage/mg/L/sample name/test date, etc.
7. Automatically store date data: year, month, day, hour, minute, second; Automatically store during power outage.
Specifications:
1 | Display | LCD |
2 | Measuring range | 3ug to 200 mg water; Water content range: 1ppm-100% |
3 | Resolution | 0.01 ug water |
4 | Accuracy | 10μg-1mg water, ± 0.2%; >1mg water, < ± 0.3% (excluding injection error) |
5 | Electrolysis speed | max 2.4 mg/min |
6 | Electrolytic current | 0~430 mA |
7 | Ambient temperature | 5~35 ℃ |
8 | Humidity | ≤85%
|
9 | Power supply | AC 220V ± 10% |
10 | Dimension | 320*240*180mm
|
11 | Weight | about 6kg |
Detail Images:
Micro Automatic Karl Fischer Micro Moisture Analyzer
This instrument adopts Karl Fischer Coulometric method. It owns advantages of high testing accuracy, good repeatability, low testing cost etc. It is used to accurately test trace water content in various liquid, solid and gases. And it is widely applied to petroleum, chemical engineering, pharmacy, electricity, scientific research, education department and so on.
Features:
1. Intelligent judgment: powerful next-generation processors; Dual CPU design. Separate electrolytic electrodes and measuring electrodes through dual power channels; Automatically eliminate various interferences; Greatly improved the accuracy of test results. Measure electrode data and directly perform A/D sampling conversion; The true value of the data avoids errors caused by analog circuits; The results are more accurate.
2. Easy to operate: Touch screen operation, only one press is needed to automatically complete the test and display the report value.
3. Background compensation: High current background compensation. The standby time can be shortened to less than 10 minutes.
4. Speed control: software adjusts the mixing speed; Choose between 0 and 36.
5. Endpoint indication: character prompt and buzzer
6. Comprehensive calculation function: automatic display, calculation, printing of ppm/percentage/mg/L/sample name/test date, etc.
7. Automatically store date data: year, month, day, hour, minute, second; Automatically store during power outage.
Specifications:
1 | Display | LCD |
2 | Measuring range | 3ug to 200 mg water; Water content range: 1ppm-100% |
3 | Resolution | 0.01 ug water |
4 | Accuracy | 10μg-1mg water, ± 0.2%; >1mg water, < ± 0.3% (excluding injection error) |
5 | Electrolysis speed | max 2.4 mg/min |
6 | Electrolytic current | 0~430 mA |
7 | Ambient temperature | 5~35 ℃ |
8 | Humidity | ≤85%
|
9 | Power supply | AC 220V ± 10% |
10 | Dimension | 320*240*180mm
|
11 | Weight | about 6kg |