The automatic closed cup flash point tester (Tag closed cup method) is designed, developed, and produced based on the national standard GB/T 21929 "Test method for flash point by tag closed cup tester" and the automatic testing method of ASTM D56. Suitable for automatically determining the flash point of liquids with viscosity less than 5.5cSt at 40 ℃, or viscosity less than 9.5cSt at 25 ℃, and flash point lower than 93 ℃.
Applicable standards:
GB/T 21929 "Test method for flash point by tag closed cup tester"
ASTM D56 "Standard Test Method for Flash Point by Tag Closed Cup Tester"
Features:
The closed cup flash point tester adopts a high-definition 7-inch high-resolution LCD touch screen display and touch screen button control.
Full English human-machine interface, displayed in English, fully automated control throughout the experiment, intuitive and easy to operate.
The closed cup flash point tester has full automation functions such as automatic lifting and lowering of the test arm, automatic cooling/heating control, automatic ignition, automatic flash point detection, saving and printing of test results, and automatic air cooling at the end of the test.
Electronic silicon carbide ignition technology, electronic flame, no need to connect to gas source, energy-saving and environmentally friendly, ensuring safe use in the laboratory.
The closed cup flash point tester uses a high-precision A-level Pt100 temperature sensor to detect temperature.
When the sample reaches the preset temperature, it automatically ignites and detects the flash point of the sample.
The closed cup flash point tester adopts a high-precision flash point detector to detect the flash point, with short response time and high sensitivity.
The digital module automatically detects atmospheric pressure, and the test results are automatically compensated to the corrected value for atmospheric pressure.
The closed cup flash point tester is equipped with a fault self diagnosis system and reminder function; Can store multiple experimental results.
Closed cup flash point tester has the function of setting time, date, and week.
Equipped with temperature limit function, the test instrument automatically stops the test and prompts when the temperature limit is reached.
At the end of the experiment, the experiment number and results will be automatically saved and printed.
Technical Parameter:
Working voltage | AC220V ± 10%, 50Hz |
Flash point test range | 5-93 ℃ (the instrument can lower the sample temperature to -5 ℃) |
Heating rate | Flash point<60 ℃ (0.9~1.1 ℃/min); Flash point ≥ 60 ℃ (2.7~3.3 ℃/min) |
Detection interval | Flash point<60 ℃ (0.5 ℃); Flash point ≥ 60 ℃ (1 ℃) |
Maximum power of the equipment | not exceeding 300W (each component does not work simultaneously) |
Heating power | 150W |
cooling power | 160W |
ignition rod power | 120W |
Operating interface | 7-inch high-resolution LCD touch screen with a resolution of 800 * 480. |
Temperature display accuracy | 0.1 ℃ |
Air pressure detection | Digital air pressure sensing chip, with an error of ± 0.3kPa @ 25 ℃. |
Refrigeration components | Semiconductor refrigeration chips with water flow switch protection function. |
Cooling and heat exchange method | circulating water cooling, randomly equipped with a submersible pump |
Printer | Embedded thermal micro printer |
Number of historical records | can store 256 sets of historical result values |
Hardware testing | equipped with switch cup cover testing, ignition mechanism testing, stirring testing, ignition rod testing, heating testing, cooling testing |
Product Details Display of Closed Flash Point Tester:
Automatic Closed Flash Point Tester by Tag Closed Cup Method
The automatic closed cup flash point tester (Tag closed cup method) is designed, developed, and produced based on the national standard GB/T 21929 "Test method for flash point by tag closed cup tester" and the automatic testing method of ASTM D56. Suitable for automatically determining the flash point of liquids with viscosity less than 5.5cSt at 40 ℃, or viscosity less than 9.5cSt at 25 ℃, and flash point lower than 93 ℃.
Applicable standards:
GB/T 21929 "Test method for flash point by tag closed cup tester"
ASTM D56 "Standard Test Method for Flash Point by Tag Closed Cup Tester"
Features:
The closed cup flash point tester adopts a high-definition 7-inch high-resolution LCD touch screen display and touch screen button control.
Full English human-machine interface, displayed in English, fully automated control throughout the experiment, intuitive and easy to operate.
The closed cup flash point tester has full automation functions such as automatic lifting and lowering of the test arm, automatic cooling/heating control, automatic ignition, automatic flash point detection, saving and printing of test results, and automatic air cooling at the end of the test.
Electronic silicon carbide ignition technology, electronic flame, no need to connect to gas source, energy-saving and environmentally friendly, ensuring safe use in the laboratory.
The closed cup flash point tester uses a high-precision A-level Pt100 temperature sensor to detect temperature.
When the sample reaches the preset temperature, it automatically ignites and detects the flash point of the sample.
The closed cup flash point tester adopts a high-precision flash point detector to detect the flash point, with short response time and high sensitivity.
The digital module automatically detects atmospheric pressure, and the test results are automatically compensated to the corrected value for atmospheric pressure.
The closed cup flash point tester is equipped with a fault self diagnosis system and reminder function; Can store multiple experimental results.
Closed cup flash point tester has the function of setting time, date, and week.
Equipped with temperature limit function, the test instrument automatically stops the test and prompts when the temperature limit is reached.
At the end of the experiment, the experiment number and results will be automatically saved and printed.
Technical Parameter:
Working voltage | AC220V ± 10%, 50Hz |
Flash point test range | 5-93 ℃ (the instrument can lower the sample temperature to -5 ℃) |
Heating rate | Flash point<60 ℃ (0.9~1.1 ℃/min); Flash point ≥ 60 ℃ (2.7~3.3 ℃/min) |
Detection interval | Flash point<60 ℃ (0.5 ℃); Flash point ≥ 60 ℃ (1 ℃) |
Maximum power of the equipment | not exceeding 300W (each component does not work simultaneously) |
Heating power | 150W |
cooling power | 160W |
ignition rod power | 120W |
Operating interface | 7-inch high-resolution LCD touch screen with a resolution of 800 * 480. |
Temperature display accuracy | 0.1 ℃ |
Air pressure detection | Digital air pressure sensing chip, with an error of ± 0.3kPa @ 25 ℃. |
Refrigeration components | Semiconductor refrigeration chips with water flow switch protection function. |
Cooling and heat exchange method | circulating water cooling, randomly equipped with a submersible pump |
Printer | Embedded thermal micro printer |
Number of historical records | can store 256 sets of historical result values |
Hardware testing | equipped with switch cup cover testing, ignition mechanism testing, stirring testing, ignition rod testing, heating testing, cooling testing |