Availability: | |
---|---|
Quantity: | |
GD-H1908
GOLD
ASTM D7097 Thermo-oxidation Engine Oil Simulation Tester TEOST MHT
Functional Characteristics:
1.The instrument can replace the similar foreign TEOST.
2.The main components are imported from abroad,including the temperature controller, deposition rod, gear pump, flow sensor, etc.
3.The working time of the instrument can be set, and it will stop automatically after the test.
4.The instrument can be tested by ASTM D6335, SH/T0750 method through additional components.
5.The instrument is equipped with a catalyst magnetic mixing device, which can set the mixing time and mixing speed.
6.Automatic electronic flow controller, accurately control the gas flow rate of 10ml±0.2ml/min.
7.All parameter settings can be performed on the touch screen, and the test can be started with one key after completion.
Application Scope:
1.Lubricant Production Enterprise
2.Related Testing Department
Related Standards:
1.ASTM D6335 Standard Test Method for Determination of High Temperature Deposits by Thermo-Oxidation Engine Oil Simulation Test.
2.ASTM D7097 Standard Test Method for Determination of Moderately High Temperature Piston Deposits by Thermo-Oxidation Engine Oil Simulation Test - TEOST MHT.
3.SH/T0834 "Determination of Engine Oil Moderately High Temperature Piston Deposits Thermal Oxidation Simulation Test Method (TEOST MHT)".
4.SH/T0750 "Determination Method of High Temperature Oxidation Deposits of Engine Oil (Thermal Oxidation Simulation Test Method)".
Technical Parameters:
Model | GD-H1908 |
Applicable Standards | ASTM D7097, SH/T0834, SH/T0750 |
Test Temperature | Room temperature - 500℃±2℃ |
Test Time | 24hrs |
Sample Amount | 8.4g |
Pump Flow Rate | 0.25g/minute |
Gas Flow Rate | 10ml±0.2ml |
Power Supply | AC220V,50Hz |
Instrument Size | 450mm*450mm*560mm |
Configuration List:
No. | Name | Specs | Qty | No. | Name | Specs | Qty | |
1 | Main unit | GD-H1908 | 1 | 13 | Micro syringe | 1 | ||
2 | Soap film flowmeter | 1 | 14 | Filter funnel | 1 | |||
3 | Mass flowmeter | 1 | 15 | MHT catalyst | 1g | |||
4 | Deposition rod | 4 | 16 | Sediment standard oil | T33C-1 | 300ml | ||
5 | Thermocouple | 2 | 17 | Sediment standard oil | MDF-4 | 50ml | ||
6 | Ceramic insulating washers | 2 | 18 | PTFE stir bar | 1 | |||
7 | O-ring | 4 | 19 | Cleaning rod | 4 | |||
8 | Glass cover | 1 | 20 | User manual | 1 | |||
9 | Collection bottle | 1 | ||||||
10 | Sample bottle | 1 | ||||||
11 | Inlet pipe | 1 | ||||||
12 | Weighing plate | 1 |
ASTM D7097 Thermo-oxidation Engine Oil Simulation Tester TEOST MHT
Functional Characteristics:
1.The instrument can replace the similar foreign TEOST.
2.The main components are imported from abroad,including the temperature controller, deposition rod, gear pump, flow sensor, etc.
3.The working time of the instrument can be set, and it will stop automatically after the test.
4.The instrument can be tested by ASTM D6335, SH/T0750 method through additional components.
5.The instrument is equipped with a catalyst magnetic mixing device, which can set the mixing time and mixing speed.
6.Automatic electronic flow controller, accurately control the gas flow rate of 10ml±0.2ml/min.
7.All parameter settings can be performed on the touch screen, and the test can be started with one key after completion.
Application Scope:
1.Lubricant Production Enterprise
2.Related Testing Department
Related Standards:
1.ASTM D6335 Standard Test Method for Determination of High Temperature Deposits by Thermo-Oxidation Engine Oil Simulation Test.
2.ASTM D7097 Standard Test Method for Determination of Moderately High Temperature Piston Deposits by Thermo-Oxidation Engine Oil Simulation Test - TEOST MHT.
3.SH/T0834 "Determination of Engine Oil Moderately High Temperature Piston Deposits Thermal Oxidation Simulation Test Method (TEOST MHT)".
4.SH/T0750 "Determination Method of High Temperature Oxidation Deposits of Engine Oil (Thermal Oxidation Simulation Test Method)".
Technical Parameters:
Model | GD-H1908 |
Applicable Standards | ASTM D7097, SH/T0834, SH/T0750 |
Test Temperature | Room temperature - 500℃±2℃ |
Test Time | 24hrs |
Sample Amount | 8.4g |
Pump Flow Rate | 0.25g/minute |
Gas Flow Rate | 10ml±0.2ml |
Power Supply | AC220V,50Hz |
Instrument Size | 450mm*450mm*560mm |
Configuration List:
No. | Name | Specs | Qty | No. | Name | Specs | Qty | |
1 | Main unit | GD-H1908 | 1 | 13 | Micro syringe | 1 | ||
2 | Soap film flowmeter | 1 | 14 | Filter funnel | 1 | |||
3 | Mass flowmeter | 1 | 15 | MHT catalyst | 1g | |||
4 | Deposition rod | 4 | 16 | Sediment standard oil | T33C-1 | 300ml | ||
5 | Thermocouple | 2 | 17 | Sediment standard oil | MDF-4 | 50ml | ||
6 | Ceramic insulating washers | 2 | 18 | PTFE stir bar | 1 | |||
7 | O-ring | 4 | 19 | Cleaning rod | 4 | |||
8 | Glass cover | 1 | 20 | User manual | 1 | |||
9 | Collection bottle | 1 | ||||||
10 | Sample bottle | 1 | ||||||
11 | Inlet pipe | 1 | ||||||
12 | Weighing plate | 1 |