| Availability: | |
|---|---|
| Quantity: | |
GD-100
GOLD
Microcoulometric Sulfur And Chlorine Analyzer
GD-100 microcoulomb sulfur and chlorine analyzer operates on the Windows win7/win10 operating system as its working platform, and its user-friendly interface facilitates more convenient and efficient operation for analysts. During the system analysis process, operating conditions, analysis parameters, and analysis results are directly displayed on the monitor. Additionally, parameters and results can be saved and printed as needed for future reference and archiving.
Working Principle:
The GD-100 microcoulometric sulfur and chlorine analyzer is a closed-loop negative feedback system, utilizing the microcoulometric titration principle and designed with a zero-balance working mode. It consists of a coulometric amplifier, a titration cell, and a suitable electrolyte.
Features:
The microcoulomb sulfur and chlorine analyzer has the most complete configuration and the widest range of use, automatically converting into corresponding parameters based on form and density, with good performance and high degree of automation.
Computer control, display the entire process status, illustrate the parameters of the entire titration process, and save data for easy retrieval and printing of various results.
The furnace body and main unit of the microcoulomb sulfur and chlorine analyzer are equipped with shielding devices, which completely eliminate the risk of furnace temperature control and also completely solve the interference with the titration cell baseline during the heating process.
The microcoulomb sulfur and chlorine analyzer is easy to operate, reliable in performance, stable, and easy to install. The cracking system is air-cooled and the fan automatically starts and stops.
Technical Parameters:
| Generated current | Maximum: ±2mA |
| Amplifier output voltage | Maximum: ±30V |
| Given bias voltage range | 0~500mv, continuously adjustable |
| Scope of analysis | (1) Sulfur: 0.2mg/L to 5000mg/L (2) Chlorine: 0.5mg/L to 5000mg/L |
| Temperature control range and accuracy | Room temperature to 1000℃, ±1%±5℃ |
| Repeatability error | (1) When the sample concentration is less than 1.0 mg/L, the repeatability error is not greater than 50% (2) When the sample concentration is between 1.0mg/L and 10mg/L, the repeatability error is not greater than 10% (3) When the sample concentration is greater than 10mg/L, the repeatability error is not greater than 5% |
Product Details of Microcoulometric sulfur and chlorine analyzer: