Availability: | |
---|---|
Quantity: | |
GD-LPC-P3
GOLD
Portable Liquid (Oil) Particle Counter for Lab or Field Oil Analysis
Application Scenarios
The Liquid Particle counter is designed on the principle of light resistance (shading method) and is used to detect the size and number of particles in the liquid. Can be widely used in aerospace, aviation, electric power, petroleum, chemical industry, traffic, port, metallurgy, machinery, automobile manufacturing and other fields in the hydraulic oil, lubricating oil, transformer oil, insulating oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluid solid particle pollution tests such as oil, And the detection of insoluble particles in organic liquid and polymer solution.
Technical Indicator
Light Sources | Semiconductor laser | Sensitivity | 0.1 μm |
Sampling volume | 0.2-6000mL | Sampling accuracy | Better than ± 1% |
Sampling speed | 5-80mL/min | Cleaning speed | 5-80mL/min |
Counting error | <±5% | Resolution | <10% |
Repeatability | RSD < 2% | Limiting Recombination Error | 12000-40000 particles/mL |
Working temperature | -20℃-60℃ | Online detection interval time | Arbitrary setting |
Power supply | AC100-240V, 50/60Hz | Battery capacity | 5200mAh |
Battery Run Time | 6-8 hours | Overall Dimension | 410*320*165mm |
Weight | 8.5kg | Temperature of test sample | 0℃-80℃ |
Particle size range | 0.8-600μm (calibrated to ACFTD calibration 1-100μm or ISO MTD calibration 4-70μm(c)) | ||
Customized detection channels | 16 channels, any particle size | ||
Off-line viscosity | <100cSt (optional pneumatic chamber for high viscosity) | ||
Pressure range | Low pressure 0~0.6Mpa, high pressure up to 42Mpa (optional pressure reducing valve) |
Core advantages of Liquid Particle counter
1.High -intensity handbox P2;
2. Adopting Die-Casting Aluminum Frame, The Panel is Made of 304 Stainless Steel, and the Instrument is Rigid.
3. High-strength suitcase type housing, easy to carry;
4. When the detection viscosity is too large, you can choose a gas compartment;
5. Built-in lithium battery, suitable for field operation ......
Comparison of key parameters of portable particle counter
Parameter | LPC-P2 | LPC-P3 | LPC-P5 | LPC-P50 | LPC-P6 |
Dimensions | 310×305×135mm | 410×320×165mm | 275×220×107mm | 365×295×170mm | 420×326×182mm |
Weight | 7.5Kg | 8.5Kg | 2.5Kg | 5.5Kg | 8.5Kg |
Screen | 5.6 inch | 5.6 inch | 3.5 inch | 10.2 inch | 7 inch |
Power source | Bidirectional piston pump | Bidirectional piston pump | Metering pump | Metering Pumps | Bidirectional piston pumps |
Battery | Built-in 5200mAh | Built-in 5200mAh | External, optional | Built-in 8000mAh, no battery indicator | Built-in 5200mAh |
Repeatability | ≤2% | ≤2% | ≤5% | ≤5% | ≤2% |
Customized Channels | 16 channels | 16 channels | No Customization | No Customization | 64 channels |
System Software | Multi-level account password login, editable test results | Multi-level account password login, editable test results | Multi-level account password login, editable test results | ||
Moisture Viscosity Temperature Function | Optional | Optional | Moisture temperature is standard. Viscosity is not optional | Moisture temperature is standard. Viscosity is not optional | Optional |
Computer function | Connectable to computer | Connectable to computer | Connectable to computer |
Operation Interface and Product picture details
Portable Liquid (Oil) Particle Counter for Lab or Field Oil Analysis
Application Scenarios
The Liquid Particle counter is designed on the principle of light resistance (shading method) and is used to detect the size and number of particles in the liquid. Can be widely used in aerospace, aviation, electric power, petroleum, chemical industry, traffic, port, metallurgy, machinery, automobile manufacturing and other fields in the hydraulic oil, lubricating oil, transformer oil, insulating oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluid solid particle pollution tests such as oil, And the detection of insoluble particles in organic liquid and polymer solution.
Technical Indicator
Light Sources | Semiconductor laser | Sensitivity | 0.1 μm |
Sampling volume | 0.2-6000mL | Sampling accuracy | Better than ± 1% |
Sampling speed | 5-80mL/min | Cleaning speed | 5-80mL/min |
Counting error | <±5% | Resolution | <10% |
Repeatability | RSD < 2% | Limiting Recombination Error | 12000-40000 particles/mL |
Working temperature | -20℃-60℃ | Online detection interval time | Arbitrary setting |
Power supply | AC100-240V, 50/60Hz | Battery capacity | 5200mAh |
Battery Run Time | 6-8 hours | Overall Dimension | 410*320*165mm |
Weight | 8.5kg | Temperature of test sample | 0℃-80℃ |
Particle size range | 0.8-600μm (calibrated to ACFTD calibration 1-100μm or ISO MTD calibration 4-70μm(c)) | ||
Customized detection channels | 16 channels, any particle size | ||
Off-line viscosity | <100cSt (optional pneumatic chamber for high viscosity) | ||
Pressure range | Low pressure 0~0.6Mpa, high pressure up to 42Mpa (optional pressure reducing valve) |
Core advantages of Liquid Particle counter
1.High -intensity handbox P2;
2. Adopting Die-Casting Aluminum Frame, The Panel is Made of 304 Stainless Steel, and the Instrument is Rigid.
3. High-strength suitcase type housing, easy to carry;
4. When the detection viscosity is too large, you can choose a gas compartment;
5. Built-in lithium battery, suitable for field operation ......
Comparison of key parameters of portable particle counter
Parameter | LPC-P2 | LPC-P3 | LPC-P5 | LPC-P50 | LPC-P6 |
Dimensions | 310×305×135mm | 410×320×165mm | 275×220×107mm | 365×295×170mm | 420×326×182mm |
Weight | 7.5Kg | 8.5Kg | 2.5Kg | 5.5Kg | 8.5Kg |
Screen | 5.6 inch | 5.6 inch | 3.5 inch | 10.2 inch | 7 inch |
Power source | Bidirectional piston pump | Bidirectional piston pump | Metering pump | Metering Pumps | Bidirectional piston pumps |
Battery | Built-in 5200mAh | Built-in 5200mAh | External, optional | Built-in 8000mAh, no battery indicator | Built-in 5200mAh |
Repeatability | ≤2% | ≤2% | ≤5% | ≤5% | ≤2% |
Customized Channels | 16 channels | 16 channels | No Customization | No Customization | 64 channels |
System Software | Multi-level account password login, editable test results | Multi-level account password login, editable test results | Multi-level account password login, editable test results | ||
Moisture Viscosity Temperature Function | Optional | Optional | Moisture temperature is standard. Viscosity is not optional | Moisture temperature is standard. Viscosity is not optional | Optional |
Computer function | Connectable to computer | Connectable to computer | Connectable to computer |
Operation Interface and Product picture details